Thermal Cameras 2026
A UK guide to selecting thermal imaging equipment based on published features.
Choose by the job
Compare native infrared resolution, sensitivity, field of view and reporting requirements before choosing a thermal camera.
Manufacturer-documented model examples
Featured models illustrate different specifications; they are not tested rankings or stock recommendations.
Compare the detector and lens
Native detector resolution, NETD and field of view describe different aspects of performance.
Professional applications
Electrical inspection, building surveys, rescue and fixed monitoring have different requirements.
Budget considerations
Check software, calibration, accessories, UK warranty and current retailer prices rather than assuming a fixed price.
Buying checklist
Verify the exact UK model, native infrared resolution, thermal sensitivity, focus, reporting features and aftercare.
Explore model guides
Thermal camera specifications at a glance
Manufacturer-published examples, not independent tests, rankings, stock or merchant offers. Check exact UK variants.
| Specification | HIKMICRO B20 | Fluke TiS20+ | FLIR C5 | FLIR E8-XT | Fluke TiS60+ | FLIR K65 | Pulsar Axion 2 XQ35 Pro | HIKMICRO M30 | HIKMICRO Falcon FQ50 (original) | Dräger UCF FireVista | Optris PI 640i | FLIR A700 Advanced Image Streaming | Bullard QXT (original X-Factor) | Guide IR510 Nano N2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Native infrared pixels | 256 × 192 | 120 × 90 | 160 × 120 | 320 × 240 | 320 × 240 | 320 × 240 | 384 × 288 | 384 × 288 | 640 × 512 | 320 × 240 | 640 × 480 | 640 × 480 | 240 × 180 or 320 × 240 (original model configurations) | 400 × 300 (17 µm detector pitch) |
| NETD | <40 mK | 60 mK | <70 mK | <50 mK | ≤45 mK | <30 mK at 30°C | <25 mK (sensor NETD) | <35 mK | <20 mK | 50 mK | 40 mK with selected lenses; 60 mK with 15°/120° optics | Lens dependent; check selected optic | Confirm original unit and detector option | Not stated in available manufacturer manual |
| Image frequency | 25 Hz | 9 Hz or 30 Hz variant | 8.7 Hz | 9 Hz | <9 Hz or 30 Hz variant | 60 Hz | 50 Hz | 25 Hz (UK listing; check regional variant) | 50 Hz | 30 Hz | 32 Hz full frame; 125 Hz at 640 × 120 | 30 Hz | Confirm exact original variant | 50 Hz |
| Field of view | 37.2° × 50.0° | 50° × 38° | 54° × 42° | 45° × 34° | 34.1° × 25.6° | 51° × 38° | 10.7° × 8° | 37.5° × 28.5° | 8.75° × 7° | 50° × 37° | Lens dependent: 15° × 11° to 120° × 100° | Lens dependent | Confirm the fitted original camera configuration | 14.6° × 11.1° (25 mm lens) |
| Minimum focus distance | 0.3 m minimum | 0.5 m minimum | 0.1 m minimum (thermal) | 0.5 m minimum | 0.46 m minimum (fixed focus) | Fixed; depth of field 0.84 m to infinity | 5 m minimum | 0.2 m minimum; manual focus | 5 m minimum | Fixed focus; manufacturer does not specify minimum in summary | Lens dependent; approximately 0.2–0.5 m | Lens dependent | Fixed-focus firefighting imager; check unit specification | Manual focus; 25 mm focal length |
| Object temperature range | −20°C to 550°C | −20°C to 150°C | −20°C to 400°C | −20°C to 550°C | −20°C to 400°C (not calibrated below −10°C) | −20°C to 150°C; 0°C to 650°C (range modes) | Not an object-temperature measuring imager | −20°C to 550°C | Not an object-temperature measuring imager | −20°C to 650°C displayed temperature range | −20°C to 900°C standard; optional range up to 1500°C | Configuration dependent; confirm precise calibrated range | Fire-service operating and measurement specifications require model-specific verification | Observation monocular, not calibrated object temperature measurement |
| Typical application | Building, HVAC and general inspection | Electrical, HVAC and facilities maintenance | Pocket-sized building and electrical inspection | Legacy handheld electrical, mechanical and building inspections | Electrical and facilities maintenance, fixed-focus inspections | Legacy specialist fire-and-rescue thermal imaging; operational procurement and training required | Discontinued outdoor thermal observation monocular; not a radiometric inspection camera | Handheld radiometric inspection for electrical, building, HVAC and automotive use | Outdoor thermal observation with 50 mm F0.9 lens; distinct from inspection cameras | Firefighting and rescue thermal imaging; specialist training and operational procurement apply | Fixed industrial thermography, research and process monitoring; USB/optional integration | Fixed industrial automation and radiometric streaming using RTSP/GVSP protocols | Legacy firefighter thermal imaging camera; not the QXT Pro with X-Factor 2.0 | Legacy outdoor wildlife and site observation; N2 versus N2 Wi-Fi variants differ |
- HIKMICRO B20 model guide · Manufacturer specification
- Fluke TiS20+ model guide · Manufacturer specification
- FLIR C5 — model guide pending · Manufacturer specification
- FLIR E8-XT model guide · Manufacturer specification
- Fluke TiS60+ model guide · Manufacturer specification
- FLIR K65 model guide · Manufacturer specification
- Pulsar Axion 2 XQ35 Pro model guide · Manufacturer specification
- HIKMICRO M30 model guide · Manufacturer specification
- HIKMICRO Falcon FQ50 (original) model guide · Manufacturer specification
- Dräger UCF FireVista model guide · Manufacturer specification
- Optris PI 640i model guide · Manufacturer specification
- FLIR A700 Advanced Image Streaming model guide · Manufacturer specification
- Bullard QXT (original X-Factor) model guide · Manufacturer specification
- Guide IR510 Nano N2 model guide · Manufacturer specification